MultiDomainControl Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 07. Components [MOST] Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Parametric Diagram
NewtonCoolingWithBlocks Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 07. Components [MOST] Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Internal Block Diagram (IBD)
Block Diagram Components - S0 - DISO Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 07. Components [MOST] Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Parametric Diagram
Block Diagram Components - SO - SISO Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 07. Components [MOST] Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Parametric Diagram
Block Connectors Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 06. Connectors Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Internal Block Diagram (IBD)
SysPhS-1.1 vs Modelica: On export the SysPhS signal flow Port types are flattened to remove the FlowProperty (rSig, iSig, or bSig). In the exported Modelica code you'll only ever see the Port names.
In this example, ports are typed by RealSignalOutElement and RealSignalInElement from the signal flow library ... which both have a flow property rSig typed by Real, from SysML, as shown in Figure 49. Source SysPhS-1.1
Figure 30: Elements for signal flow Gallery Tutorial TRAIL: SysPhS-1.1 specification body figures in MagicDraw/Cameo SysML vs Modelica [using Wolfram SystemsModeler] Section Slide kind SysML Package Diagram
SysPhS-1.1: When RealSignalInElement or RealSignalOutElement are used to type a SysML Port, assignments to the FlowProperty 'rSig' map to the Port name (only) when mapped to Modelica.
SysPhS-1.1: p.47: 10.12.2 SysML modeling: References to 'u.sigsp' and 'y.usigsp' should be 'u.rSig' and 'y.rSig'.
Figure 22: Ports for signal flow in SysML Gallery Tutorial TRAIL: SysPhS-1.1 specification body figures in MagicDraw/Cameo SysML vs Modelica [using Wolfram SystemsModeler] Section Slide kind hybrid diagram SysML Block Definition Diagram (BDD)